The Accu-Chek Inform II is a portable blood glucose monitoring system designed for healthcare professionals to measure glucose levels in clinical settings efficiently and accurately;
It combines advanced technology with user-friendly design, offering reliable results for patient care. The system integrates with laboratory information systems for streamlined data management.
1.1 Overview of the Accu-Chek Inform II Blood Glucose Meter
The Accu-Chek Inform II is a portable blood glucose meter designed for healthcare professionals to measure glucose levels in clinical settings. It offers fast and accurate results, with a small blood sample requirement of 0.6 µL and a testing time of just 5 seconds.
The meter is compatible with Accu-Chek Inform II test strips and features a user-friendly interface. It is intended for use in hospitals, clinics, and other healthcare facilities, providing reliable glucose monitoring for multiple patients.
1.2 Key Features and Benefits
The Accu-Chek Inform II offers quick and accurate blood glucose results, requiring only 0.6 µL of blood and providing results in 5 seconds. Its user-friendly design and compatibility with laboratory information systems enhance clinical workflow efficiency. The meter supports data management, enabling healthcare professionals to track patient trends effectively. Its portability and reliability make it ideal for use in various healthcare settings, ensuring accurate and efficient glucose monitoring for improved patient care.
1.3 Intended Use for Healthcare Professionals
The Accu-Chek Inform II is designed for healthcare professionals to measure blood glucose levels in multiple patients within clinical settings. It is intended for in vitro diagnostic use, providing quantitative glucose measurements from capillary whole blood samples. The system supports efficient patient monitoring and data management, making it suitable for use in hospitals, clinics, and other healthcare facilities where accurate and reliable glucose testing is essential for patient care.
Components and Accessories of the Accu-Chek Inform II
The Accu-Chek Inform II system includes a portable meter, test strips, control solutions, and additional accessories like coding keys and a base unit for seamless operation and accuracy.
2.1 Meter Description and Parts
The Accu-Chek Inform II meter is a compact, portable device designed for clinical use. It features a backlit display for easy reading, a strip port for test strip insertion, and a power button for operation. The meter includes an infrared (IR) port for data transfer and is powered by a lithium battery, ensuring long-lasting performance. Its lightweight and durable design makes it suitable for healthcare settings, providing reliable glucose monitoring.
2.2 Test Strips and Their Specifications
The Accu-Chek Inform II test strips require 0.6 μL of blood for precise glucose measurement, providing results in 5 seconds. They measure glucose levels between 0.56 and 33.3 mmol/L, ensuring accurate readings. Each vial contains 50 strips and a code chip for automatic calibration. Designed for ease of use, the strips feature a wide mouth for easy blood application, making them reliable for healthcare professionals in clinical settings. Always check the expiry date and store properly for optimal performance.
2.3 Control Solutions and Calibration Requirements
The Accu-Chek Inform II requires high and low control solutions for quality control tests to ensure accurate results. These solutions verify the meter’s performance and compatibility with test strips. Regular testing with control solutions is essential to maintain precision and reliability in clinical settings.
Calibration is automatic with the code chip provided on each test strip vial. Ensure control solutions are used before expiration and stored properly; The meter also performs self-checks at startup to confirm readiness for testing, ensuring compliance with clinical standards for reliable glucose monitoring.
2.4 Additional Accessories for Effective Use
The Accu-Chek Inform II system includes various accessories to enhance functionality. These include test strip vials with code chips, control solutions for quality checks, and a power supply for the base unit. Additional accessories like barcode scanners facilitate quick patient and operator ID entry, while data management kits enable seamless connectivity to laboratory systems. A carrying case is also available for convenient transport, ensuring all components are organized and easily accessible.
Getting Started with the Accu-Chek Inform II
Unpack and prepare the meter, ensuring all components are included. Follow setup instructions for initial use, including entering operator and patient information for accurate tracking.
3.1 Unpacking and Preparing the Meter
Begin by carefully unpacking the Accu-Chek Inform II system, ensuring all components are included. Remove the meter from its protective covering and insert the battery or charge it as per the manual. Locate the test strips and control solutions, checking their expiration dates. Enter the code from the test strip vial into the meter to ensure accurate readings. Perform a quality control test using the control solution to verify proper calibration and functionality before initial use. This step ensures the meter is ready for precise blood glucose monitoring.
3.2 Setting Up the Meter for First-Time Use
Power on the meter by pressing and holding the power button until the display lights up. Insert the battery or connect the power supply as instructed. Set the date and time using the navigation buttons. Enter the meter’s code by scanning or manually inputting it from the test strip vial. Perform a quality control test using the provided control solution to ensure accuracy. This initial setup ensures the meter is ready for precise glucose monitoring.
3.3 Entering Operator and Patient Information
Enter your operator ID by scanning a barcode or manually inputting it. For patients, scan their barcode armband or manually enter their complete CSN. Ensure all information is accurately entered to maintain patient records. The system allows multiple patient profiles to be stored for quick access. This step ensures data traceability and compliance with clinical protocols, making patient care more organized and efficient in healthcare settings.
Measuring Blood Glucose with the Accu-Chek Inform II
Power on the meter, insert a test strip, and apply a small blood sample to the strip. The meter quickly provides accurate glucose results for patient assessment.
4.1 Step-by-Step Testing Procedure
Turn on the Accu-Chek Inform II by pressing the power button. Insert a test strip into the meter, ensuring it clicks into place. Obtain a blood sample via fingerstick. Gently touch the blood to the test strip’s tip, filling the sample area completely. The meter analyzes the sample and displays the glucose result within seconds. Refer to the manual for detailed instructions and troubleshooting guidance if needed.
4.2 Handling and Applying the Blood Sample
Obtain a blood sample using a sterile lancet. Gently press the lancet against the fingertip to collect a small blood drop. Avoid squeezing the finger excessively, as this may alter blood composition. Hold the test strip vertically and touch the blood drop to the designated sample area. Ensure the strip fills completely for accurate results. Dispose of used lancets and strips safely following biohazard protocols.
4.3 Interpreting Test Results and Displays
The Accu-Chek Inform II displays blood glucose results in numerical format, with optional units (mg/dL or mmol/L). The meter shows “HI” for results above the measurable range and “LO” for results below. Ensure the reading is within the target range. If an error symbol appears, refer to the troubleshooting section. Always verify results align with the patient’s condition and consult the operator’s manual for detailed guidance on interpreting symbols and codes.
Quality Control and Calibration
The Accu-Chek Inform II requires regular quality control tests using high and low-level solutions to ensure accurate readings and proper calibration per the operator’s manual.
5.1 Performing Quality Control Tests
Performing quality control tests ensures the Accu-Chek Inform II system operates accurately. Use high and low-level control solutions as specified. Insert a test strip, apply the control solution, and wait for results. Compare the readings with the expected range on the vial. Document the results and perform troubleshooting if values are out of range. Always refer to the operator’s manual for detailed procedures and guidelines.
5.2 Calibrating the Meter for Accuracy
Calibrating the Accu-Chek Inform II ensures precise glucose readings. Use the provided control solutions and follow the operator’s manual instructions. Insert a test strip, apply the control solution, and wait for the result. Ensure the displayed value matches the expected range on the control solution vial. Proper calibration is essential for accurate test results and should be performed as directed to maintain system reliability and compliance with clinical standards.
Troubleshooting Common Issues
Address error messages like “HI” for high blood glucose or “LO” for low readings. Check strip expiration, ensure proper calibration, and verify battery life for optimal performance.
6.1 Identifying and Resolving Error Messages
The Accu-Chek Inform II displays error messages like “HI” or “LO” for out-of-range results. Ensure test strips are valid, not expired, and properly inserted. If “E-1” appears, re-insert the strip or replace it. Calibration errors require using the correct code chip. Refer to the operator’s manual for detailed troubleshooting steps to resolve issues quickly and maintain accurate glucose monitoring. Proper handling ensures reliable results and system functionality.
6.2 Addressing Common Operational Problems
Common issues include meter malfunction or incorrect readings. Ensure the meter is clean and stored properly. Test strips must be used before their expiry date and handled correctly to avoid contamination. Verify proper calibration and code chip alignment. If issues persist, consult the operator’s manual or contact technical support. Regular maintenance and adherence to guidelines ensure optimal performance and accurate blood glucose measurements in clinical settings.
Safety and Regulatory Information
Ensure proper handling and storage of the meter between 5°C and 40°C with 10-85% humidity. Follow safety precautions to prevent exposure to blood or contaminants, ensuring accurate results and user protection.
7.1 Proper Handling and Storage of the Meter
To maintain the Accu-Chek Inform II’s performance, store the meter in a clean, dry environment between 5°C and 40°C (41°F to 104°F) with humidity levels between 10% and 85%. Avoid exposure to extreme temperatures, moisture, or direct sunlight. Regularly clean the meter with a soft cloth and mild detergent, ensuring no liquids enter the strip port or other openings. Proper storage prevents damage and ensures accurate test results for reliable patient care.
7.2 Safety Precautions for Healthcare Professionals
Healthcare professionals should handle the Accu-Chek Inform II with care to avoid exposure to blood or other biological fluids. Always wear gloves when performing tests and ensure proper hand hygiene. Avoid touching the test strip opening or electrical components to prevent contamination. Regularly disinfect the meter according to the manufacturer’s guidelines to maintain a sterile environment and prevent the risk of infection transmission, ensuring patient and user safety.