This guide details the Simon XT system, covering setup, operation, and troubleshooting. It includes information on wireless zones, mobile app access, and system customization options.
The Simon XT system provides robust home security, offering a blend of wireless convenience and reliable protection. Designed for ease of use, it caters to both standard and advanced security needs, supporting up to 40 wireless zones – with options for hardwired connections as well. This system empowers users with operational control and features like remote access via a dedicated mobile application.
Key components include a central control panel, wireless sensors (door/window contacts, motion detectors), and optional accessories. The system’s architecture allows for flexible configuration, adapting to various home layouts and security requirements. It’s a comprehensive solution for safeguarding your property and loved ones.
System Components and Package Contents
A standard Simon XT package typically includes a control panel, wireless door/window contacts, and a motion detector. Additional components may include a wireless keypad for convenient arming/disarming, and a siren for audible alerts. The system supports both Crystal and SAW Learn technology for sensor compatibility.
Optional accessories enhance functionality, such as smoke detectors, carbon monoxide sensors, and water leak detectors. The package also contains mounting hardware, batteries for sensors, and a comprehensive user manual. Verify all listed items are present upon delivery to ensure a complete setup. Refer to the included documentation for specific component details.

Setting Up Your Simon XT System
Initial setup involves activating the control panel, configuring wireless zones, and optionally installing hardwired zones for comprehensive security coverage.
Initial System Activation
To begin, insert the provided SIM card into the control panel, ensuring correct orientation. Power on the panel using the included power adapter and allow it to initialize. Follow the on-screen prompts to select your language and time zone.
Next, you’ll need to create a master user code – choose a secure, memorable code. The system will then guide you through a cellular communication test to verify signal strength. Successful completion confirms the panel can connect to the monitoring center. Finally, register your system online using the provided serial number for full access to remote features and support.
Wireless Zone Configuration
Wireless zone configuration involves pairing sensors with the control panel. Enter the system’s programming mode via the menu. To add a sensor, initiate “learn mode” on the panel and then activate the sensor – typically by removing its battery or pressing a learn button.
The panel will display a zone number upon successful enrollment. Assign descriptive names to each zone (e.g., “Front Door,” “Living Room Window”). You can configure zone types (entry/exit, interior, etc.) and adjust sensitivity settings to minimize false alarms. Repeat this process for each wireless sensor.
Hardwire Zone Installation
Hardwire zone installation connects wired sensors directly to the Simon XT control panel. This typically involves running wires from door/window contacts or motion detectors to designated terminals on the panel’s circuit board. Ensure the system is powered off before making any connections.
Refer to the wiring diagram in the manual for correct terminal assignments. Properly ground all wiring to prevent interference. After wiring, configure the zones in the system menu, specifying the zone type and activation method (normally open or normally closed). Test each hardwired zone to confirm proper functionality.

Understanding the Control Panel
The control panel is the central hub of the Simon XT system, displaying system status, allowing arming/disarming, and managing user codes and settings.
Control Panel Display and Indicators
The Simon XT control panel features a user-friendly display providing crucial system information. Key indicators include a “System Ready” light, confirming proper operation and communication with the monitoring center. A disarmed icon signifies the system isn’t actively protecting your premises, while an armed icon (away or stay) indicates active security.
Trouble lights alert you to issues like low batteries in sensors or communication failures. A flashing alarm light signifies an active alarm event. The display also shows zone status – open or closed – during arming and disarming sequences. Understanding these indicators is vital for effective system management and responding to potential security breaches promptly. Regularly check the panel for any unusual activity.
Navigating the System Menu
Accessing the Simon XT system menu allows for customization and detailed control. Typically, you’ll use the keypad to enter a master code, granting access to programming options. Within the menu, you can manage user codes, adjust entry/exit delays, and configure zone settings.
Scrolling through options is usually done with up/down arrow keys, and selections are confirmed with an “Enter” or “Save” key. Be cautious when altering settings, as incorrect configurations can impact system performance. The menu structure is logically organized, but consulting the full user manual is recommended for complex adjustments. Remember your master code for future access!
Arming and Disarming the System
The Simon XT system offers multiple arming modes for flexible security. “Stay” arming secures the perimeter while allowing movement inside, ideal for nighttime. “Away” arming activates all sensors, suitable when the premises are vacant. Disarming requires entering a valid user code via the keypad.
Ensure all doors and windows are closed before arming to prevent false alarms. The system provides audible and visual confirmation of arming/disarming status. Remote arming/disarming is possible through the mobile app or web portal, offering convenience and control from anywhere with an internet connection. Always verify the system status!

Sensor Management
Effectively manage your Simon XT sensors by adding new wireless devices, replacing batteries promptly, and resolving any communication or functionality issues.
Adding Wireless Sensors
To add a wireless sensor to your Simon XT system, begin by entering the system’s programming mode via the control panel menu. Select the “Add Sensor” option, and the system will initiate a listening period. Activate the sensor by removing its battery tab or following the manufacturer’s specific instructions for enrollment.
The control panel should then display a confirmation message indicating successful sensor registration. Assign a descriptive zone name to the newly added sensor for easy identification during events. Ensure the sensor is within range of the control panel for reliable communication. Repeat this process for each additional sensor you wish to incorporate into your security network.
Replacing Sensor Batteries
Low battery alerts from your Simon XT sensors indicate it’s time for a replacement. Access the sensor by carefully removing its cover, typically by sliding or unclipping it. Dispose of the old battery responsibly, following local regulations. Insert a new battery of the correct type, ensuring proper polarity alignment – positive and negative terminals must match.
Reattach the sensor cover securely. The system should automatically recognize the new battery and cease the low battery alert. Test the sensor by triggering it to confirm proper functionality. Regularly scheduled battery replacements, typically every 1-2 years, maintain optimal system performance.
Troubleshooting Sensor Issues
If a sensor malfunctions, first check the battery level within the Simon XT system menu. Ensure the sensor is within range of the control panel; obstructions can interfere with the wireless signal. Verify the sensor hasn’t been physically tampered with or moved from its designated zone.
Attempt to re-sync the sensor with the control panel through the system settings. If issues persist, consult the Simon XT manual for specific error codes. Contact customer support for assistance with complex problems or sensor replacements, providing the sensor’s ID for efficient troubleshooting.

System Programming and Customization
Customize your Simon XT system by managing user codes, naming zones, and adjusting entry/exit delays for personalized security settings and optimal performance.
User Code Management
Creating and managing user codes is crucial for controlling access to your Simon XT system. You can add multiple users, each with a unique code, granting specific permissions. Master codes provide full system control, while individual user codes limit access to arming and disarming.
Regularly update user codes to enhance security, especially after personnel changes. The system allows for easy code modification and deletion through the control panel menu. Remember to keep master codes confidential and avoid easily guessable combinations. Proper user code management ensures only authorized individuals can interact with your security system, protecting your property and peace of mind.
Zone Naming and Configuration
Customizing zone names within the Simon XT system enhances clarity and simplifies system monitoring. Instead of generic labels like “Zone 1,” assign descriptive names such as “Front Door,” “Living Room Window,” or “Basement Motion Detector.” This makes identifying triggered alarms significantly easier and faster.
Configuration options allow you to define each zone’s sensor type (door, window, motion), entry/exit delay settings, and alarm response characteristics. Accurate zone configuration ensures the system reacts appropriately to specific events. Regularly review and update zone names and settings to reflect any changes in your home’s layout or security needs.
Entry and Exit Delay Settings

Simon XT’s entry and exit delay settings are crucial for preventing false alarms. Exit delays provide a timeframe to leave the premises after arming the system, while entry delays allow time to disarm upon entering. These timers are adjustable to suit your lifestyle and routines.
Proper configuration prevents the alarm from triggering during normal entry or exit. Consider the time needed to reach the control panel and enter your code. Shorter delays offer quicker response, but risk false alarms; longer delays provide convenience but may compromise security. Regularly review and adjust these settings as needed.

Advanced Features
Explore remote access, event log reviews, and the Simon XT mobile app for enhanced control and monitoring of your security system’s performance.
Remote Access and Control
The Simon XT system offers convenient remote access and control capabilities, allowing users to manage their security from virtually anywhere with an internet connection. This functionality is primarily facilitated through the Simon XT mobile app, providing a user-friendly interface for arming, disarming, and checking the system status.
Users can also receive real-time notifications regarding alarm events, sensor activity, and system alerts directly on their smartphones or tablets. Furthermore, remote access enables users to review the event log, providing a detailed history of system activity. This feature enhances peace of mind and allows for proactive security management, even when away from home.
Event Log Review
The Simon XT system meticulously records all security-related events in a comprehensive event log, accessible through both the control panel and the mobile app. This log provides a chronological history of arming/disarming actions, sensor triggers, alarm activations, and system errors.
Reviewing the event log is crucial for understanding system activity, identifying potential issues, and verifying the effectiveness of security measures. Users can typically filter the log by date, time, and event type to quickly locate specific information. Detailed entries offer valuable insights into system performance and can aid in troubleshooting any unexpected behavior or security breaches.
Simon XT Mobile App Guide
The Simon XT mobile app extends the functionality of your security system directly to your smartphone or tablet, offering remote control and monitoring capabilities. Through the app, users can arm and disarm the system, receive real-time alerts for alarms or sensor triggers, and view the event log for a detailed history of system activity;
The app also allows for user code management, enabling you to add or delete authorized users and customize their access levels. Furthermore, it provides access to system settings, allowing for adjustments to zone configurations and notification preferences, ensuring a personalized and secure experience.

Maintenance and Troubleshooting
Regular system testing, battery checks, and understanding error codes are crucial for optimal performance and reliability of your Simon XT security system.
System Testing Procedures
To ensure your Simon XT system functions correctly, perform regular tests. Begin by initiating a walk test through the system menu; this verifies each sensor communicates with the control panel. Test all door and window sensors, motion detectors, and any other connected devices. Confirm the central monitoring station receives the signals during the walk test.
Additionally, periodically test the system’s communication with the monitoring center by triggering an alarm and verifying a prompt response. Check the siren’s functionality to ensure it’s audible throughout your property. Document all test results and address any failures immediately to maintain a secure environment. Consistent testing is vital for peace of mind.
Low Battery Alerts and Solutions
The Simon XT system provides low battery alerts for both sensors and the control panel itself. These alerts appear on the control panel display and may also be communicated via the mobile app or monitoring center. Upon receiving a low battery notification, promptly replace the batteries in the affected sensor. Use only the recommended battery type, typically AA or AAA.
For the control panel, ensure the power adapter is securely connected and functioning. If the issue persists, contact customer support. Ignoring low battery alerts can lead to system failure, compromising your security. Keep spare batteries readily available for quick replacement.
Common Error Codes and Resolutions
The Simon XT system utilizes error codes to indicate specific issues. A “Check System” message often signals a communication problem with a sensor; verify sensor placement and battery levels. “Sensor Offline” indicates a lost connection, requiring re-pairing or battery replacement. “Low Battery” necessitates immediate battery changes.
If you encounter an unfamiliar error code, consult the full Simon XT manual or the manufacturer’s website for detailed explanations and troubleshooting steps. Contacting customer support with the specific error code will expedite resolution. Regularly testing the system helps identify and address potential issues proactively.

Technical Specifications
The Simon XT operates on wireless frequencies, offering a substantial range. It requires a standard power supply and functions within defined environmental operating conditions.
Wireless Frequency and Range
The Simon XT system utilizes a secure wireless frequency to communicate between the control panel and its various sensors. While the specific frequency isn’t explicitly detailed in the provided snippets, reliable communication is paramount for system effectiveness. The range of this wireless communication is substantial, allowing for coverage of a typical residential property.
Factors influencing the range include building materials, potential interference from other wireless devices, and the placement of the control panel. Optimal sensor placement is crucial to ensure consistent connectivity. The system supports up to 40 wireless zones, demonstrating its capacity for extensive home protection. Understanding these factors helps maximize the system’s performance and reliability.
Power Supply Requirements
The Simon XT system requires a reliable power source for consistent operation. Information gleaned from the provided data references an “ACUMULADOR ESTATICO 1600W ACE-1601,” suggesting a static accumulator with a 1600W capacity is utilized, likely as a backup power solution. The primary power source is expected to be standard AC power, delivered through a compatible power adapter.
A backup battery is essential to maintain security during power outages. The system is designed to seamlessly switch to battery power, ensuring continued monitoring and alarm functionality. Regular testing of the backup battery is recommended to verify its operational readiness and longevity, safeguarding against unexpected disruptions in service.
Environmental Operating Conditions
The Simon XT system is designed for indoor use within specific environmental parameters. While detailed specifications aren’t explicitly provided in the source material, optimal performance relies on maintaining a stable temperature and humidity level. Avoid exposing the control panel and sensors to extreme temperatures, direct sunlight, or excessive moisture.
Operating the system in environments outside of its intended range can lead to malfunctions or reduced battery life. It’s crucial to protect the equipment from dust, dirt, and corrosive substances. Proper placement and regular cleaning will contribute to the longevity and reliability of the Simon XT security system, ensuring consistent protection.

Safety Information
Always heed safety precautions when installing and using the Simon XT system. Be aware of potential electrical hazards and follow regulatory compliance guidelines carefully.
Important Safety Precautions
Prior to installation and operation of your Simon XT system, carefully review these crucial safety guidelines. Always disconnect power before working with any wiring to prevent electrical shock. Ensure all components are properly secured to avoid falling hazards.
Do not attempt to disassemble or repair the control panel or sensors yourself; contact qualified technicians for assistance. Keep the system away from extreme temperatures and moisture. The lightning flash symbol indicates potential electrical danger – exercise extreme caution; Proper disposal of batteries is essential, following local regulations. Regularly test the system to confirm functionality and ensure your safety.
Regulatory Compliance
The Simon XT system is designed to comply with relevant industry regulations and standards. This includes adherence to FCC guidelines regarding radio frequency emissions, ensuring minimal interference with other devices. The system also meets established safety standards for electrical components and battery operation.
Furthermore, the device is designed to operate within legal limits for wireless communication frequencies. Users should be aware of and comply with local regulations concerning alarm system installation and monitoring. Compliance documentation is available upon request, detailing specific certifications and testing results for the Simon XT system.
Disposal and Recycling
Proper disposal of the Simon XT system and its components is crucial for environmental responsibility. Do not dispose of the control panel, sensors, or batteries with general household waste. Batteries, in particular, require special handling due to their chemical composition.
Consult local regulations for designated battery recycling locations. Electronic components should be recycled through certified e-waste recycling facilities. This ensures valuable materials are recovered and hazardous substances are managed safely. Contact your local waste management authority for guidance on appropriate disposal methods in your area.